Verified from the manual · Updated October 2026

Alto-Shaam steam oven error codes

31 codes for Combitherm CT PROformance series (including Prodigi 7-20 Pro) commercial combi ovens, transcribed from the official documentation with page references.

Commercial ovens log codes to an error history. Press Start to acknowledge; the oven then tries to resume. Codes marked service need an Alto-Shaam authorized service provider.

Code What it means Likely cause What to do Service?
E01 Low water in steam generator (roll-in models). Water supply shut off or low pressure; calcium on the water-level probe; fill solenoid, drain pump or drain cap faults. Check the water supply and pressure and descale the generator; otherwise service. Call service
E02 Control (relay board) temperature above 176°F / 80°C. Cooling fan malfunction or blocked air intake. Clear the air intake; service if the fan has failed. Call service
E03 Fan motor error (table-top / upper motor). Motor or fan wheel locked, or the Hall-effect sensor does not detect rotation. Service. Call service
E04 Lower fan motor error (roll-in models). Lower convection fan does not spin within 60 seconds. Service. Call service
E05 / E06 VFD communication failure (upper / lower). Loss of power to the VFD, CAN cable disconnected, VFD or control board fault. Service. Call service
E07 / E08 Error reported by the VFD (upper / lower). See the VFD error list and match the number of green-LED blinks. Service. Call service
E11 Convection temperature high (cavity above 600°F / 315°C for 25 s). Convection element contactor locked on, or cavity probe N6 malfunction. Service. Call service
E13 Steam generator temperature high (above 248°F / 120°C for 25 s). Calcium on the water-level probe or in the generator; steam element contactor locked on; probe B4 fault. Descale; service if it persists. Call service
E15 Condenser temperature high (above 212°F / 100°C). Water supply shut off, plugged steam bypass hose, or cooling-water solenoid Y2 fault. Check the water supply; service if it persists. Call service
E20 Single-point core temperature probe fault. Probe not inserted into food correctly, not connected, dirty receptacle pins, or a failed probe. Re-seat the probe and clean the receptacle pins; replace the probe if it persists. Owner fix
E21 Cavity temperature probe (N6) fault. Probe malfunction or disconnected wires. Service. Call service
E22, E26–E29 Multipoint core probe (B10) fault, whole probe or points 1–4. Probe malfunction or disconnected wires. Service. Call service
E23 / E24 / E25 Steam generator (B4) / bypass (B5) / condenser (B3) probe fault. Probe malfunction or miswired. Service. Call service
E34 Steam generator drain pump fault during cleaning. Calcium build-up or blockage in the drain pump, pump failure, or water-level probe failure. Descale; service if it persists. Call service
E36 Steam temperature high. Water supply shut off or low; calcium on the water injection pipe or flow restrictor; solenoid Y1 fault; blocked bypass hose. Check the water supply and descale; service if it persists. Call service
E40–E49 A temperature probe is shorted to ground (B3, B4, B5, N6, N8, B10 and its points). Probe miswired or failed. Service. Call service
E51 No water in steam generator (roll-in models). Water supply shut off, or relay board fault. Open the water supply; service if it persists. Call service
E53 / E54 Fan motor over-temperature (upper / lower), above 320°F / 160°C. Motor high-limit open or miswired, motor or fan wheel locked, fan wheel damaged. Service. Call service
E55 / E56 Vent did not open within 60 seconds (lower / upper vent). Vent valve monitoring switch or vent motor fault. Service. Call service
E57 No rinse water detected for 60 seconds. Water supply shut off or low pressure; flow switch dirty or failed. Check the water supply; clean the flow switch. Owner fix
E88 / E89 Gas ignition failure (lower / upper). Gas supply shut off or low; hot-surface igniter, flame sensor, ignition control or gas valve fault; plugged heat exchanger. Check the gas supply. If it appears a third time after two resets, remove the oven from service and contact an authorized provider. Call service
E90 / E91 Gas combustion blower not at speed (lower / upper). Power or speed-control cable not connected, blower blocked or failed, faulty control board. Service. Call service
E92 / E93 / E94 Communication error between the control board and the interface board. CAN cable connection or cable fault, relay or display board connector fault. Turn the oven off, disconnect power, reconnect and turn on. Check the CAN cable connections; service if it persists. Owner fix
E100 A maintenance reminder has timed out. A reminder expired without action. Open the maintenance reminder screen, address the item and reset. Owner fix
E101 / E102 Ventless hood fault: no pressure / filters not present. Filters missing, clogged or not seated; hood fan, filter switch or pressure switch fault. Install, clean or re-seat the hood filters; a cook cycle cannot start until cleared. Owner fix
E103 / E104 Option board not communicating. CAN cable between option board and control board, DIP switch setting, or incompatible software. Service. Call service
E105 No or low water pressure. Water supply not connected, shut off, or blocked (check the filter). Connect or open the water supply; clean the inlet filter. Owner fix
E108 Cooling fan failure (board between 140°F and 176°F). Cooling fan malfunction or blocked air intake. Clear the intake; service if the fan has failed. Call service
E109 High-limit switch open. An overheat condition, cooling fan failure, heat relay stuck closed, or a faulty high-limit connection. Press the high-limit reset once. If the condition remains, contact an Alto-Shaam service provider. Call service
E200 SD card larger than 2 GB detected. Wrong SD card size. Contact service to order a replacement SD card. Call service
E210–E217 VFD under-voltage, over-voltage, overheating, motor over-current, current peak, EEPROM error, over-current, short circuit. Blocked fan wheel, cooling fan failure, convection motor or VFD malfunction. Service. Call service

Source: Alto-Shaam Combitherm CT PROformance operator\'s manual MN-35948 Rev 21, p. 79.

Before you call Alto-Shaam

  1. Refill and re-seat the water tank, and straighten any inlet or drain hose you can reach.
  2. Run the descale program if the oven has one, with the manufacturer's descaler, not vinegar.
  3. Switch the oven off at the wall for a minute and back on. One power-cycle is in nearly every manual; repeated resets are not.
  4. If the same code returns, note it with the serial number and book service. Every sensor, probe, fan or board code above is listed by Alto-Shaam as a service call.

Maintenance that prevents the water codes

Regular descaling with the product your manual names prevents most of the scale-related faults above. Affiliate links, at no cost to you.

Durgol Swiss Steamer descaler

A general-purpose steam-oven descaler, for ovens whose manual allows a generic one (Anova says any descaling liquid works). Miele and Thermador name their own descalers; use those instead.

View on Amazon · ~$21
Miele descaling tablets

The tablets Miele's own descale program expects. Clears the F20 message on DGC combi-steam ovens.

View on Amazon · ~$22
Weiman stainless microfiber cloth

A soft, non-abrasive cloth for drying the door and cavity after a steam cycle. Every manual we checked rules out scouring pads and abrasive cleaners.

View on Amazon · ~$9
All steam oven accessories →