Verified from the manual · Updated October 2026
Wolf steam oven error codes
78 codes for Wolf convection steam ovens (CSO24, CSO30 and CSO3050 E-series/M-series, plumbed CSOP models); codes show as E-numbers, often paired with an F/U/A message on legacy displays, transcribed from the official documentation with page references.
| Code | What it means | Likely cause | What to do | Service? |
|---|---|---|---|---|
| E01 (shown with message F5) | Control board fault | Problems with control board caused by moisture or EMC influences | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E02 (shown with message F5) | Control board fault | Control board issues caused by moisture or EMC influence | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E03 (shown with message F5) | Control board / process data fault | Loaded incorrect process data; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E04 (shown with message F5) | Process data or software fault | Process data error; Reload software error | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E05 (shown with message F5) | Control fault (legacy models) | Not stated in the article | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E09 (shown with message F0) | Oven temperature sensor (PT sensor) short circuit | Short circuit in PT sensor or in its wiring | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E11 (shown with message F0) | Processor fault | Processor faulty | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E12 (shown with message F0) | Processor or control board fault | Processor faulty; Control board issue; Temperature invalid | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E13 | Heating relay or temperature fault; maximum cavity temperature reached | Electromagnetic disturbances; Heating and main relay short circuited; Temperature sensor, relay error, or a programming issue; Reached maximum cooking space temperature | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E16 (shown with message A1) | Operation timed out waiting for input (door closed, tank filled) | Maximum hold time exceeded; An operation timed out while waiting for input | The oven cancels an operation left on hold (door open or tank empty) for more than 1-3 hours. Turn the home circuit breaker off for 30 seconds and back on; retest. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E17 (shown with message F1) | Food probe short circuit | Short circuit in food probe or in its wiring; Food probe not inserted into food, tip too hot; Moisture in food probe socket; Food probe temperature short circuit | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E18 (shown with message F1) | Food probe open circuit or loose contact | Break or loose contact in food probe or probe socket; probe wiring broken or loose contact; food probe resistance too high | Press the light button to clear the error; unplug the probe; check the probe receptacle for debris (canned air can help); reinsert the probe and test. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E25 (shown with message F3) | Climate sensor short circuit or blocked duct | Short circuit in climate sensor or in its wiring; Exhaust duct blocked; Duct between cooking space and sensor blocked | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E26 (shown with message F3) | Climate sensor open circuit or blocked duct | Break or loose contact in climate sensor or in its wiring; Exhaust duct blocked; Duct between cooking space and sensor blocked | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E27 (shown with message F17) | Climate sensor fault or over-temperature at sensor | Hairline crack in climate sensor; Temperature limit of the temperature sensor 300C exceeded; Excessively warm air flowing over the temperature sensor 300C during self-clean from a bad door gasket | No customer troubleshooting is published; contact Wolf Factory Certified Service for repair | Call service |
| E29 (shown with message F9) | Cooking space not sealed; too much cold food | Cooking space not tightly sealed; Door not closed properly; Exhaust slide valve not tight; Food probe socket issue; Too much cold food in the cooking space; Food probe socket dirty or wet; Hot air fan seal is missing or faulty; Slider stuck or defective; Seal or conduit to cavity defective; Too much cold food in cavity | Verify quantity of frozen food in unit; When steaming, weight of frozen food should not exceed 6.5 lb or 3 kg; Verify door is closed during use. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E33 (shown with message F12) | Power unit temperature sensor short circuit / relay board moisture | Processor faulty; Excessive moisture on the relay board; Short circuit in power unit temperature sensor | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E34 (shown with message F12) | Relay board open circuit | Processor faulty; Relay board open circuit | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E35 (shown with message F13) | Cabinet (niche) over-temperature or cooling fan fault | Cabinet opening temperature too high (may be caused by second appliance); Cool air fan failure; Power failure during operation; Over temperature | Reset the unit at the circuit breaker; Turn the unit back on to see if the error code reappears. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E36 (shown with message F14) | Control unit short circuit | Control unit faulty; Control board short circuit | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E37 (shown with message F14) | Control unit temperature sensor open circuit | Control issue; Open circuit in control unit temperature sensor | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E38 (shown with message F15) | Niche temperature too high | Niche temperature too high; Second appliance generating excess heat near appliance; Cool air fan issue; Power failure during operation | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E41 (shown with message F2) | Water temperature sensor short circuit or boiler leak | Short circuit in water temperature sensor or in its wiring; Boiler leaking water | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E42 (shown with message F2) | Water system fault (no customer detail published) | Not stated in the article | No customer troubleshooting is published; contact Wolf Factory Certified Service for repair | Call service |
| E44 (shown with message F7) | Boiler heating fault or over-temperature protection | Break in flange (fastening screws not tightened enough, etc.); Heating element for boiler faulty; Over-temperature protection activated; Food probe socket dirty or wet; Boiler very scaled up; Defective evaporator heater; Temperature sensor 100C temperature limiter is not resetting; Defective level measure pin | No customer troubleshooting is published; contact Wolf Factory Certified Service for repair | Call service |
| E45 (shown with message F8) | Actuator relay K3 stuck | Actuator relay K3 stuck; Element or relay board damaged | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E46 (shown with message F8) | Actuator relay K4 stuck | Actuator relay K4 stuck; Element or relay board damaged | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E47 (shown with message F8) | Actuator relay K5 stuck or not connected | Actuator relay K5 stuck or not connected; Element or relay board damaged | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E48 (shown with message F8) | Actuator relay K6 stuck or relay supply fault | Actuator relay K6 stuck; Element or relay board damaged; Relay supply circuit defective or plug not fitted correctly | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E49 (shown with message F10) | Button jammed or moisture on control unit | Button is mechanically blocked or jammed; Moisture on the control unit; Element or relay board damaged | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E50 (shown with message F10) | Moisture on control unit; room air fan not working; steam leak | Moisture on the control unit; Room air fan not working; Steam leak | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E51 (shown with message F6) | Relay calibration / neutral wiring fault | Software error on appliances with K3.20398-0 or K3.20398-1 software; neutral and pole conductor swapped on a 1-phase connection; processor faulty | No customer troubleshooting is published (the article notes a relay board replacement is the service fix); contact Wolf Factory Certified Service for repair | Call service |
| E52 (shown with message F10) | Water tank valve not tight | Water tank valve not tight | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E57 (shown with message U0) | Mains voltage too high at L1 (over 280 VAC) or neutral fault | Product connected to neutral conductor terminal; Neutral wire break in the house wiring system; Mains calibration error; Voltage at L1 greater than 280 VAC for more than three seconds | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E58 (shown with message U1) | No voltage at L2 or breaker tripped | No pole conductor connected to L2 clamp; Circuit breaker or fuse in the house wiring system activated; L2 voltage - over voltage | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E59 (shown with message U0) | Mains voltage at L1 low (155-176 VAC) or neutral break | Over voltage in mains electrical supply; Neutral conductor break in the house wiring system; Mains calibration error; Voltage at L1 was between 155 VAC and 176 VAC | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E61 (shown with message U2) | Mains under-voltage | Under voltage in mains power supply; Main calibration error | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E62 (shown with message U3) | Mains under-voltage | Under voltage in mains power supply; Mains calibration error | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E63 | Mains voltage not calibrated / low voltage | No calibration of main voltage, processor issue; Low voltage | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E66 | Boiler scaled or thermal cutout tripped | Boiler scaled up; Thermal cutout tripped; Microcontroller voltage on sensor module too low | Descale the oven if it has not been done recently. See CSO Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E67 (shown with message F20) | Boiler scaled or hose kinked; temperature sensing fault | Boiler scaled up; Silicon hose kinked; Temperature sensing issue | Turn the home circuit breaker to the unit off for 30 seconds and back on again. Retest the unit operation; Descale the oven if it has not been done recently. See CSO Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E68 | Boiler scaled, inlet valve leaking, foam in boiler or tank leaking | Boiler scaled up; Inlet valve leaking (valve not tight, limescale fragments in seal, etc.); Foam in the boiler housing (especially after descaling); Water tank is leaking | Descale the oven if it has not been done recently. See also, CSO Descaling; Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E69 (shown with message F21) | Boiler scaled, inlet valve leaking, foam or tank microswitch fault | Boiler scaled up; Inlet valve leaking (valve not tight, limescale fragments in seal, etc.); Foam in the boiler housing, especially after descaling; Water tank microswitch | No customer troubleshooting is published. The article notes that if descaling was done recently, the water system pumping off water at least three times within 2 hours or a non-recommended descaling solution that foams can trigger it; contact Wolf Factory Certified Service for repair | Call service |
| E70 | Boiler scaled or inlet valve leaking | Boiler scaled up; Inlet valve leaking (valve not tight, limescale fragments in seal, etc.) | Descale the oven if it has not been done recently. See CSO Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E71 (shown with message F22) | Boiler scaled, inlet valve leaking, tank motor or door lock fault | Boiler scaled up; Inlet valve leaking; Short circuit in the drive motor for the water tank; Pyrolysis door lock circuit defective | Descale the oven if it has not been done recently. See CSO Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E72 | Drain pump moving too little water or water conductivity too low | Drain pump pumping off too little water; Water conductivity too low; Foam in boiler housing (unsuitable descaling agent); Open circuit in the drive motor of the water tank; Top heat actuator defective or not connected | Verify Convection Steam Oven water requirements are met. See CSO Water Requirements; Descale the product if it has not been done recently. See CSO Oven Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E73 (shown with message F23) | Drain pump moving too little water or water conductivity too low | Drain pump pumping off too little water; Water conductivity too low; Foam in boiler housing (unsuitable descaling agent) | Verify the water requirements for the Convection Steam Oven are met. See CSO Water Requirements; Descale the product if it has not been done recently. See CSO Oven Descaling. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E74 | No descaling solution detected / level measurement error | No descaling solution added during descaling; Error in measurement of level (possibly due to formation of foam); Retractable handle issues; Grill actuator defective or not connected | For knob control models, verify descaling solution was added to the unit if descaling is in process. See CSO Oven Descaling; Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E75 (shown with message F22) | Insufficient rinse water or excessive foam | Insufficient amount or no water for rinsing; Excessive build-up of foam; Retractable handle issue; Bottom heat actuator issue | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E76 | Insufficient rinse water or excessive foam | Insufficient amount or no water for rinsing; Excessive build-up of foam; Retractable handle issue | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E77 (shown with message F22) | Exhaust slide valve stuck or slide motor short | Exhaust slide valve stuck with grease deposits; Motor or slide valve jammed (mechanical defect); Short circuit in slide motor or in its wiring | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E78 (shown with message F24) | Drain sump level sensor fault (plumbed CSOP models) | Draining of plumbed CSO; Drain Sump level sensor pin dirty; Short circuit in Drain Sump level sensor; Short circuit in Sensor Module | Flush drain with plenty of hot water to clean grease off level sensor pin. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E84 | Slider not initialized | Slider not initialized | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E85 (shown with message F4) | Slide or stepper motor short circuit | Short circuit in slide motor or in its wiring; Short circuit in stepper motor | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E86 (shown with message F4) | Slide or stepper motor open circuit | Break or loose contact in slide motor or in its wiring; Open circuit in the stepper motor | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E87 (shown with message F4) | Exhaust slide valve stuck or slider blocked | Exhaust slide valve stuck with grease deposits; Motor or slide valve jammed (mechanical defect); Short circuit in slide motor or in its wiring; Slider blocked | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E88 | Exhaust slide valve stuck or slider in stop position | Exhaust slide valve stuck with grease deposits; Motor or slide valve jammed; Slider in stop position | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E97 | Operating system fault | Operating system issue | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E98 | Operating system fault | Operating system issue | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E99 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E100 | Operating system fault or moisture on relay board | Operating system issue; Moisture on relay board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E105 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E106 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E107 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E108 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E109 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E110 | Operating system fault or moisture on control board | Operating system issue; Moisture on control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E111 (shown with message F5) | Operating system / control board fault | Operating system issue; Control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E112 (shown with message F5) | Operating system / relay board fault | Operating system issue; Relay board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E113 | Operating system / control board fault | Operating system issue; Control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| E114 | Operating system / control board fault | Operating system issue; Control board | Turn the home circuit breaker to the unit off for 30 seconds then back on again; Retest the unit operation. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| Fatal Error. Please check software and hardware configuration! | Software/hardware configuration fault | Not stated in the article | No customer troubleshooting is published; contact Wolf Factory Certified Service for repair | Call service |
| F1 | Food probe fault | Food probe not inserted into food; moisture in the food probe socket; food probe needs to be replaced | Verify the probe is inserted into food and fully seated in the socket; turn the home circuit breaker off for 30 seconds and back on; retest. If the code remains, contact Wolf Factory Certified Service for repair | Call service |
| Boiler scaled up, please descale! | The steam boiler needs descaling | Limescale build-up in the boiler; interval depends on water hardness (every 6-18 months) | Run the Descale cycle (Settings > Descale) using Durgol Swiss Steamer descaling solution; see guide p. 14 | Owner fix |
| Appliance blocked, descaling necessary | The oven has locked out steam functions until it is descaled | Descaling overdue | Run the Descale cycle (guide p. 14). If the message does not disappear after descaling, contact Wolf Factory Certified Service | Call service |
| Do not remove water tank | Boiler water has not yet been pumped back to the tank | Water in the boiler is not pumped off until its temperature drops below 175 F (80 C) | Wait for the oven to cool and the message to clear before removing the tank | Owner fix |
| Add 1 pt (0.5 L) descaler-and touch ENTER | Descale cycle prompt to add descaling solution | Descale cycle started from Settings | Pour the entire Durgol Swiss Steamer descaling solution into the water tank and touch ENTER (guide p. 14) | Owner fix |
| Pour away descaler-fill with water | Descale cycle prompt to empty the tank and refill for rinsing | Descaling phase (about 30 minutes) is complete | Dilute and pour away the descaler, fill the tank with fresh water and continue; the display then shows Descale appliance-1st rinsing cycle and finally Descaling completed (guide p. 14) | Owner fix |
Sources: Convection Steam Oven Error Code E01 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E02 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E03 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E04 (Sub-Zero Wolf support article); Legacy Convection Steam Oven Error Code E05 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E09 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E11 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E12 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E13 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E16 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E17 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E18 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E25 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E26 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E27 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E29 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E33 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E34 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E35 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E36 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E37 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E38 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E41 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E42 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E44 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E45 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E46 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E47 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E48 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E49 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E50 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E51 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E52 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E57 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E58 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E59 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E61 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E62 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E63 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E66 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E67 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E68 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E69 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E70 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E71 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E72 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E73 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E74 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E75 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E76 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E77 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E78 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E84 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E85 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E86 (Sub-Zero Wolf support article); Wolf Convection Steam Oven Error Code E87 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E88 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E97 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E98 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E99 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E100 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E105 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E106 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E107 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E108 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E109 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E110 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E111 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E112 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E113 (Sub-Zero Wolf support article); Convection Steam Oven Error Code E114 (Sub-Zero Wolf support article); Convection Steam Oven Fatal Error Message (Sub-Zero Wolf support article); Convection Steam Oven Displays Error F1 (Sub-Zero Wolf support article); Wolf Convection Steam Oven Use and Care Guide (csoven-ucg-v2.pdf), p. 17 Troubleshooting.
Before you call Wolf
- Refill and re-seat the water tank, and straighten any inlet or drain hose you can reach.
- Run the descale program if the oven has one, with the manufacturer's descaler, not vinegar.
- Switch the oven off at the wall for a minute and back on. One power-cycle is in nearly every manual; repeated resets are not.
- If the same code returns, note it with the serial number and book service. Every sensor, probe, fan or board code above is listed by Wolf as a service call.
Maintenance that prevents the water codes
Regular descaling with the product your manual names prevents most of the scale-related faults above. Affiliate links, at no cost to you.
A general-purpose steam-oven descaler, for ovens whose manual allows a generic one (Anova says any descaling liquid works). Miele and Thermador name their own descalers; use those instead.
View on Amazon · ~$21The tablets Miele's own descale program expects. Clears the F20 message on DGC combi-steam ovens.
View on Amazon · ~$22A soft, non-abrasive cloth for drying the door and cavity after a steam cycle. Every manual we checked rules out scouring pads and abrasive cleaners.
View on Amazon · ~$9